708 research outputs found

    Nambu-Goto string action with Gauss-Bonnet term

    Full text link
    We examine the relativistic Nambu-Goto model with Gauss-Bonnet boundary term added to the action integral. The system is analysed using an invariant representation of dynamical string degrees of freedom by complex Liouville fields. The solutions of classical equations of motion for open strings are described.Comment: 9 pages, late

    An Optical Approach to the Dynamical Casimir Effect

    Full text link
    We recently proposed a new approach to analyze the parametric resonance in a vibrating cavity based on the analysis of classical optical paths. This approach is used to examine various models of cavities with moving walls. We prove that our method is useful to extract easily basic physical outcome.Comment: 9 page

    Which femoral neck for a dual mobility cup? A biomechanical evaluation.

    Get PDF
    This study aimed to evaluate polyethylene (PE) damage and wear lesions to the chamfer of mobile components under mobile and fixed femoral neck impingement at the third articulation, and to determine which femoral neck characteristics should be considered with a dual mobility cup to limit those lesions. Two femoral neck geometries (cylindrical and quadrangular) with two surface finishing roughness (rough and polished), and two head-to-neck ratios (28- and 22.2-mm diameter femoral heads) were evaluated in a hip simulator testing. For each characteristic, six femoral necks were tested with six dual mobility cups under fixed and mobile femoral neck impingement conditions. Chamfer PE damage and volumetric wear were evaluated and compared for each femoral neck characteristic and impingement condition. Under mobile impingement condition, femoral neck characteristics did not significantly affect PE damage and wear lesions to the chamfer (p = 0.283 to 0.810). However, under fixed impingement condition, significantly higher PE damage and wear lesions to the chamfer were produced by the quadrangular geometry compared to the cylindrical geometry (p = 0.004 to 0.025). In addition, with the quadrangular geometry, rough surface finishing was demonstrated to increase volumetric wear of the chamfer (p = 0.009). No significant influence of head-to-neck ratio was observed on PE damage and wear lesions to the chamfer (p = 0.244 to 0.714). This biomechanical study emphasized that femoral neck characteristics are critical with dual mobility cup and tend to favor a cylindrical geometry particularly whether fixed impingement at the third articulation occurs

    Total knee arthroplasty improves the quality-adjusted life years in patients who exceeded their estimated life expectancy.

    Get PDF
    Total knee arthroplasty (TKA) is the treatment of choice for end-stage osteoarthritis though its risk-benefit ratio in elderly patients remains debated. This study aimed to evaluate the functional outcome, rates of complication and mortality, and quality-adjusted life years (QALY) in patients who exceeded their estimated life expectancy. Ninety-seven TKA implanted in 86 patients who exceeded their estimated life expectancy at the time of TKA were prospectively included in our institutional joint registry and retrospectively analyzed. At latest follow-up, the functional outcome with the Knee Society Score (KSS), rates of complication and mortality, and QALY with utility value of EuroQol-5D score were evaluated. At a mean follow-up of three ± one years, the pre- to post-operative KSS improved significantly (p < 0.01). The rates of surgical and major medical complications related to TKA were 3% and 10%, respectively. The re-operation rate with readmission was 3% while no TKA was revised. The 30-day and one year mortality was 1% and 3%, respectively. The pre- to one year post-operative QALY improved significantly (p < 0.01). The cumulative QALY five years after TKA was four years. Assuming that these patients did not undergo TKA, their cumulative QALY at five years would have been only two years. TKA is an effective procedure for the treatment of end-stage osteoarthritis in patients who exceeded their estimated life expectancy. TKA provided significant improvement in function and quality of life without adversely affecting overall morbidity and mortality. Therefore, TKA should not be contra-indicated in elderly patients based on their advanced age alone

    Exact closed form analytical solutions for vibrating cavities

    Full text link
    For one-dimensional vibrating cavity systems appearing in the standard illustration of the dynamical Casimir effect, we propose an approach to the construction of exact closed-form solutions. As new results, we obtain solutions that are given for arbitrary frequencies, amplitudes and time regions. In a broad range of parameters, a vibrating cavity model exhibits the general property of exponential instability. Marginal behavior of the system manifests in a power-like growth of radiated energy.Comment: 17 pages, 7 figure

    Open strings with topologically inspired boundary conditions

    Full text link
    We consider an open string described by an action of the Dirac-Nambu-Goto type with topological corrections which affect the boundary conditions but not the equations of motion. The most general addition of this kind is a sum of the Gauss-Bonnet action and the first Chern number (when the background spacetime dimension is four) of the normal bundle to the string worldsheet. We examine the modification introduced by such terms in the boundary conditions at the ends of the string.Comment: 12 pages, late

    Polyethylene wear of dual mobility cups: a comparative analysis based on patient-specific finite element modeling.

    Get PDF
    Concerns remain about potential increased wear with dual mobility cups related to the multiple articulations involved in this specific design of implant. This finite element analysis study aimed to compare polyethylene (PE) wear between dual mobility cup and conventional acetabular component, and between the use of conventional ultra-high molecular weight PE (UHMWPE) and highly cross-linked PE (XPLE). Patient-specific finite element modeling was developed for 15 patients undergoing primary total hip arthroplasty (THA). Five acetabular components were 3D modeled and compared in THA constructs replicating existing implants: a dual mobility cup with a 22.2-mm-diameter femoral head against UHMWPE or XLPE (DM22PE or DM22XL), a conventional cup with a 22.2-mm-diameter femoral head against UHMWPE (SD22PE) and a conventional cup with a 32-mm-diameter femoral head against UHMWPE or XLPE (SD32PE or SD32XL). DM22PE produced 4.6 times and 5.1 times more volumetric wear than SD32XL and DM22XL (p < 0.0001, Cohen's d = 6.97 and 7.11; respectively). However, even if significant, the differences in volumetric wear between DM22XL and SD32XL as well as between DM22PE and SD22PE or SD32PE were small according to their effect size (p < 0.0001, Cohen's |d|= 0.48 to 0.65) and could be therefore considered as clinically negligible. When using XLPE instead of UHMWPE, dual mobility cup with a 22.2-mm-diameter femoral head produced a similar amount of volumetric wear than conventional acetabular component with a 32-mm-diameter femoral head against XLPE. Therefore, XLPE is advocated in dual mobility cup to improve its wear performance

    Total hip arthroplasty through the direct anterior approach with and without the use of a traction table: a matched-control, retrospective, single-surgeon study.

    Get PDF
    Hip surgeons performing total hip arthroplasty (THA) through the direct anterior approach (DAA) commonly use a traction table to facilitate exposure. Even though performing THA through DAA without a traction table could be technically more demanding, this technique offers the advantage of intraoperative leg length comparison. Therefore, this study aimed to compare clinical outcomes, complication rates, component positioning, and leg length discrepancy (LLD) after THA through the DAA performed with or without a traction table. A single-surgeon continuous series of 75 patients who underwent DAA THA performed with a traction table was matched for gender, age, and BMI with 75 patients who underwent DAA THA performed without a traction table (male, 62; female, 88, with an average age of 68 years old). Clinical and radiological outcomes, intra- and postoperative complications, and LLD were retrospectively assessed. No statistically significant difference was detected in surgical time, hospital stay, Harris Hip Score (HHS), complication rates, and implant positioning between the two groups. Leg length restoration was significantly more accurate in the group performed without a traction table (2.4 ± 2 mm vs. 3.7 ± 3.1 mm; p value ≤ 0.05). No LLD > 10 mm was reported in the group performed without a traction table, whereas two cases (2.7%) were reported in those performed with a traction table. Performing THA through DAA without a traction table was associated with a significantly more accurate leg length restoration without a significant increase in the rates of intra- and postoperative complications

    Assessing the Gene Content of the Megagenome: Sugar Pine (Pinus lambertiana).

    Get PDF
    Sugar pine (Pinus lambertiana Douglas) is within the subgenus Strobus with an estimated genome size of 31 Gbp. Transcriptomic resources are of particular interest in conifers due to the challenges presented in their megagenomes for gene identification. In this study, we present the first comprehensive survey of the P. lambertiana transcriptome through deep sequencing of a variety of tissue types to generate more than 2.5 billion short reads. Third generation, long reads generated through PacBio Iso-Seq have been included for the first time in conifers to combat the challenges associated with de novo transcriptome assembly. A technology comparison is provided here to contribute to the otherwise scarce comparisons of second and third generation transcriptome sequencing approaches in plant species. In addition, the transcriptome reference was essential for gene model identification and quality assessment in the parallel project responsible for sequencing and assembly of the entire genome. In this study, the transcriptomic data were also used to address questions surrounding lineage-specific Dicer-like proteins in conifers. These proteins play a role in the control of transposable element proliferation and the related genome expansion in conifers
    corecore